Temperature & Humidity Test Lab UK
We have a large range of climatic chambers, ranging in size from 200 to 1,500 litre, with varying capabilities:
- -70°C to +180°C at up to 20°C/min
- 15%RH to 95%RH between +20°C and +95°C
The chambers can be used for both steady state conditions and cyclic tests and all chambers have port hole access for the connection of external test equipment to the samples within the chamber.
Some of the environmental test standards that we test in accordance with are:
- BS EN 60068-2-1: Cold
- BS EN 60068-2-2: Dry Heat
- BS EN 60068-2-14: Change of Temperature
- BS EN 60068-2-30: Damp Heat Cyclic
- BS EN 60068-2-38: Composite Temperature & Humidity Cyclic
- BS EN 60068-2-78: Damp Heat Steady State
- MIL-STD-810: Method 501: High Temperature
- MIL-STD-810: Method 502: Low Temperature
- MIL-STD-810: Method 507: Humidity
- DEF STAN 00-35: Test CL2: High Temperature Low Humidity
- DEF STAN 00-35: Test CL5: Low Temperature
- DEF STAN 00-35: Test CL6: Constant High Temperature High Humidity
- DEF STAN 00-35: Test CL14: Thermal Shock & Rapid Rate of Change of Temperature
- RTCA DO-160: Section 4: Temperature
- RTCA DO-160: Section 5: Temperature Variation
- RTCA DO-160: Section 6: Humidity
This is not an exclusive list; so if you have requirements to other test standards, please contact us and we will confirm if we can provide a UKAS accredited test to meet your requirements.